Unable to Create Sequence in Oracle DB
Sometimes CREATE SEQUENCE may not work in Oracle database when the replication is run. In such cases sync_id will not be created. Hence an error will generate after running replication.
Solution:
This issue can be resolved by executing the following query in Oracle data base before running the replication. This query will create sequence hence create sync_id.
CREATE SEQUENCE "DBSYNC"."SYNCH_SEQ" MINVALUE 1 MAXVALUE 9999999999999999999999999999 INCREMENT BY 1 START WITH 1 CACHE 20 NOORDER NOCYCLE ;
CREATE SEQUENCE "DBSYNC"."NEXTVAL" MINVALUE 1 MAXVALUE 9999999999999999999999999999 INCREMENT BY 1 START WITH 1 CACHE 20 NOORDER NOCYCLE ;